FXS Parameters

The analog parameters are described in the table below.

General Analog Parameters

Parameter

Description

'Update Port Info'

[AnalogPortInfo_x]

Defines a descriptive name for an analog port. This can be used to easily identify the port.

The valid value is a string of up to 40 characters. By default, the value is undefined.

Note:

For the ini file parameter, the x denotes the port number.
To configure a port name through the Web interface, see Configuring Name for Telephony Ports.

FXS Parameters

'FXS Coefficient Type'

configure voip > interface fxs-fxo > fxs-country-coefficients

[FXSCountryCoefficients]

Determines the FXS line characteristics (AC and DC) according to USA or Europe (TBR21) standards.

[66] Europe = TBR21
[70] USA = (Default) United States

Note: For the parameter to take effect, a device reset is required.

[EnablePulseDialDetection]

Enables the device to detect pulse (rotary) dialing from analog equipment (e.g., telephones) connected to the device's FXS port interfaces.

[0] = Disable (default)
[1] = Enable

Note: For the parameter to take effect, a device reset is required.